Lost your password? Please enter your email address. You will receive a link and will create a new password via email. Sorry, you do not have permission to ask a question, You must log in to ask a question. Join now! Do you need to remove the ads? Notwithstanding any provisions provided, in any one of these bye-laws, every factory building or part thereof shall comply with the following additional regulations:.
For cities having no development plans, the factory site shall have to be approved by the authority. All the stairs shall have an unobstructed head room of at least 2.
In straight treads, the run of the treads shall not be less than 25 cm wide and the rise shall not be more than 18cm high. The width of the tread including nosing shall not be less than 27 cm.
Every staircase provided above shall be lighted and ventilated from an air space of not less than 3m depth, measured horizontally in case of ground and one upper floor structure, 4. Every person who undertakes construction of a factory building shall construct lobby, landing corridor or passage included in such work that it shall in no part be less than 1. Every hoist-way or lift-way inside a factory building shall be completely enclosed with fire-resisting materials and means of access to that hoist or lift, shall be fitted with doors of fire-resisting materials, provided that such hoist-way or lift-way shall be enclosed only at the top by some material easily broken by fire or be provided a vent at the top.
Escape arrangements should be fully in terms of section 38 7 of the Indian Factories Act, These should be provided at all times for each person employed in any room of the factory at least 3.
The internal heights of a work room shall not be less than 4. Not more than three-fifths area of the site may be covered subjected to the mandatory open spaces specified as above:.
Join Join TheConstructor to ask questions, answer questions, write articles, and connect with other people. Have an account? Factory Buildings News — latest additions to this page, arranged chronologically:. In order to achieve an integrated organization, we used a spatial diagram, which defined both the inside and outside of the project simultaneously.
This is a project that has rescued an important example of mid-century modernism and answers questions about how best and most economically we can re-use under-performing and outmoded structures, rather than building from scratch. This is an industrial complex, close to Bilbao, done as a result of two idea competitions. The Technology Park is a center of high technology industries turns 25 in For guidelines last phase of industrial growth decided to build two new buildings for research and production, respectively, computing and biotechnology.
Both of them should work in complete independence, although the plan was considered in a unified way. For the design of the this textile factory building, effective inputs were the technical descriptions of the cyclic relations of these types of productions, the limited size of the area, and the constraints of service and main road connection possibilities and those of the local production techniques.